Pilot test (model
test)
|
1.
Validate the clear effect of water purification process application,
products and design
to purify the SS/TDS, hardness, bacteria, organic matter, chemical clear 2.
Validate the clear effect of wastewater purification process design,
application and products,to purify the SS/BOD/COD, toxic chemical, heavy metal clear
|
|
The
purification rate analysis of purification products, design and
application:
1.
If not established the instant decomposing, purification and separation
design and
application
to purify the contaminants clear effectively, purified the water, waste
water up to crystal clear, the purification rate of long times
purification effect up
to
99~99.9% and the the maximum instant purification rate up to 90~99%
2.
If can be established the instant decomposing, purification and separation
design
and
application to purify the contaminants clear effectively, purified the
water,
wastewater up to crystal clear, the instant purification rate are
easy to be controlled up to 99~99.9% |
|
[purpose]
to
validate and confirm the clear purification effect of water, wastewater
product
and
design being applied at the water, wastewater purification process design
and application to purify the contaminations clear [analysis]
a.
to validate and confirm the clear unit operation purification functional
effect,
times,
efficacy, and purification rate
of each kind of water, wastewater
purification
product, design and application for effective
water, wastewater
purification
process design and application
b.
to validate and confirm the clear process purification functional effect,
times,
efficacy,
and purification rate
whether can be purified the contaminations clear
up
to crystal clear water to meet EPA city water standard and EPA 1st
class wastewater discharged standard or not [point]
a.
The correct unit operation unit pilot test of
water, wastewater purification product,
design and
application are needed to establish the instant clear purification effect
to
purify the
complex
contaminations clear at high purification rate and purify the
water,
wastewater up to crystal clear water
simultaneously
for effective
water,
wastewater
purification process design and application
b.
The correct process operation pilot test of
water, wastewater purification product,
design and
application are needed to establish the instant clear purification effect
to
purify the
complex
contaminations clear at high purification rate and purify the
water,
wastewater up to crystal clear water simultaneously
to
meet EPA city water standard and EPA 1st class wastewater discharged standard
c.
The conventional pilot test are normally used at the batched, single
element, fixed
contaminants
and long times purification effect to purify the contaminations clear
up
to crystal clear water at high purification rate, but the test result can
not matched
the
practical process
purification effect to purify all the contaminants clear up to
crystal
clear water at high purification rate for effective purification
treatment, Due to the purification effect are different at conventional pilot test and conventional
practical
process purification application:
a)
during purification treatment, the contaminations of conventional pilot
test are
batched,
fixed and easy to be controlled to be decomposed and purified clear at
long times purification treatment
b)
during purification treatment, the contaminations of conventional process
design
are always varied, hard to be decomposed and purified clear instanlty
c)
the conventional process purification design and application (except
RO/distiller)
have not instant separation design to purify and separate the
contaminants out of
process water and wastewater, during the
purification treatment, the contents of
contaminations would
be accumulated increasingly to be reduced down the process purification effect effectively, like:
1.
biotreatment:
a)
the SS/BOD/COD purification rate of conventional random
test
up to 80~90%
b)
the SS/BOD/COD purification rate of conventional process
purification
treatment are normally up to 70~75%
c)
if not controlled the filamental organisms effectively, the
SS/
BOD/COD
purification rate are reduced down to <50~70%
2.
5~1 micron filter:
a) the purification rate of random test can be purified the
bacteria,
molds, organisms clear up to 90~99%, reduced
the
bacteria count down to <100
CFU/ml
b)
the purification effect of 5~1 micron filter can be purified
the
microorganisms clear up to 90~99%, or reduced the
bacteria
count down to <100 CFU/ml at initially use
c)
If not controlled the 5~1 micron
filter at aseptic process
purification
application, after 3~7 days filtration, the
purified
water will be contaminated with 105 CFU/ml bacterial contaminations |
|
1.
The pilot test of conventional purification products, design and
application
(except
RO/distiller unit) are hard to be established the instant purification
effect
to purify the water, wastewater up to crystal clear at high purification
rate,
So the test result are only acted as the reference data, but can not applied
at
the
practical
water, waste
water purification process
design and
application 2.
The purification effect of nano-polymer pilot test are same as
RO/distiller unit
which
can be purified the contaminations of water, wastewater clear up
to
crystal
clear water at high purification rate, So it can be replaced the
distiller/
RO
unit to do effective water,
waste water purification process
design and application |
The comparison of RO/distiller and Nano-polymer application
|
1.
The purification effect of RO/distiller are designed at the invariable
purification
rate
to do the fixed and tough purification design and application
a.
purification rate:
RO unit: 90~99%
distiller unit: 85~99%
b.
purification effect: to purify and separate all the contaminants clear up
to crystal clear
water
instantly and simultaneously (contaminants
out of purified water)
1)
RO unit are suitable for low contaminations of clear water and waste
water
purification treatment application
2)
distiller unit are suitable for all contamination contents
of water and
waste
water purification treatment application
a)
to distillate the high SS/BOD/COD contaminations of water,
wastewater up to transparent clear water, wastewater effectively
b)
to distillate the low SS/BOD/COD
contaminations of water, waste
water up to crystal clear water, wastewater effectively 2.
The purification effect of Nano-polymer are designed at the variable
purification
rate
to do the simple, convenient, effective purification design and
application
a.
purification rate:
adjustment to 50~99.5% up to dosage application
b.
purification effect: to purify all the contaminants clear up to crystal
clear water instantly
and
simultaneously (contaminants
still within the purified water and
needed
to be separated after purification treatment)
a)
to purify the high SS/BOD/COD contaminations of water, waste
water up to transparent clear water, wastewater effectively
b)
to purify the low SS/BOD/COD contaminations of water, waste water up to crystal clear water, wastewater effectively |
|
[Standard test sample]
to inspect and determine the decomposing and purification rate by the color concentration
A. bio
dye:
to act as the reference of bacteria, virus, algae, microorganisms
endotoxin,
pyrogen
and biotoxin experimental purification test
B. organic
dye:
to act as the reference of organic matter, organic chemical,
organic
foulant,
odour, colour, hydrocarbon experimental purification test
C. inorganic
dye:
to
act as the reference of inorganic matter, inorganic chemical, inorganic foulant, ions, heavy metal experimental purification test
D. milk,
coolant:
to act as the reference of oil, grease, emulsions, lipase, gel,
colloids,
protein
experimental purification test
[remarks]
applied the food grade dye for city water, drinking water purification
test |
The pilot test of Nano-polymer
| To validate the high efficient design of low dosage, low costs and high purification rate purification effect for effective purification process design and application |
[The
batched pilot test]
1.
operation procedure
|
2.
operation step [step
1]
sampling
20 liters water, wastewater, wasted solutions into barrel-1 for
batched
pilot test, take 200 cc sample S1 to check SS/BOD/COD contents [step
2]
add
20~40 cc cc polymer A diluent into barrel-1, mixing 1~2 minutes, [step
3]
add
20~40 cc polymer B diluent into barrel-1, mixing 1~2 minutes,
take
200 cc sample S2 to check SS/BOD/COD contents
repeat
step 2, 3 procedure for further effective purification effect [step
4]
add
20~40 cc polymer A diluent into barrel-1, mixing 1~2 minutes, [step
5]
add
20~40 cc polymer B diluent into barrel-1, mixing 1~2 minutes,
take
200 cc sample S3 to check SS/BOD/COD contents |
[The
continuous pilot test]
1.
operation procedure
|
2.
operation step [step
1]
continuous transported 1000 liters water, wastewater into barrel-1
for the
mixing & reaction tanks, take 200 cc sample S1 to check SS/BOD
[step
2]
continuous add 1~2 liters polymer A diluent and 1~2 liters polymer
B diluent
into barrel-1 continuous mixing & reaction tanks, mixing 1~2
minutes, [step
3]
the reacted water, wastewater are continuous flowing into the
sedimentation reaction
tanks
for effective purification reaction and sedimentation [step
4]
after step 3 sedimentation reaction, the purfied water, wastewater
are through the
continuous
purification & separation design and unit for purify the purified
water
clear and feedback the coagulated silt into barrel-1 continuous
mixing & reaction
tanks for further effective purification application, take 200 cc
sample S2 to check
SS/BOD/COD
contents [step 5] to check S1, S2 SS/BOD/COD/TDS contents and monitor the SS/BOD/COD/TDS, colour,
heavy metal purification & removing rate for effective
purification process design and application |
Bright Glory enterprise,Co.Ltd/
SanDa membrane &
Nano,Co.Ltd
5F-3,
No.162, Sec. 4, Chunghsiao E. Road, Taipei, Taiwan
Tel:
886-02-2731-8306
Fax: 886-02-2731-8221
web site: www.bge.com.tw web site: http://3w.bge.com.tw Email: hong@bge.com.tw